Electricity
Electrolysis Apparatus
ELECTRODES, FLAT WITHOUT BINDING POSTS
|
For assembling voltaic cells, electrolysis experiments etc.
Size (l x w), 125 x 25mm.
|
| Material |
Cat. No. |
| Aluminum |
3151-01 |
| Carbon |
3151-02 |
| Copper |
3151-03 |
| Iron |
3151-04 |
| Lead |
3151-05 |
| Zinc |
3151-06 |
ELECTRODES, FLAT WITH BINDING POSTS
|
Size (l x w), 125 x 50mm with 4mm socket binding post terminal.
|
| Material |
Cat. No. |
| Aluminum |
3151-21 |
| Carbon (125x25mm) |
3151-22 |
| Copper |
3151-23 |
| Iron |
3151-24 |
| Lead |
3151-25 |
| Zinc |
3151-26 |
ELECTRODE, CARBON ROD
3151-41
|
For electrolysis of reactive materials like hydrochloric acid and other
compounds. Suitable alternative to platinum. Size (l x d), 150 X 5mm.
Alligator clips can be used for making wire connections.
|
VOLTAMETER, COPPER
3153-00
|
For measuring the quantity of electricity from the mass of copper deposited
on one of its electrodes.
Consists of three copper plates suspended from a bakelite cover of a plastic
jar. Outer two electrodes acting as double anode are connected to one
binding post on the top. The third inner copper plate fixed to another
binding post acts as a cathode and can easily be removed for weighing.
|
HOFFMAN ELECTROLYSIS APPARATUS
3155-01
|
For qualitative and quantitative study of the electrolytic decomposition
of electrolytes such as water, hydrochloric acid etc.
Consists of two vertical 50mL, gas-collecting, graduated glass tubes with
stopcocks at top and joined by a bridging tube to a reservoir and fitted
with a pair of platinum electrodes at the lower ends of the glass tubes.
A lead wire connecting the platinum electrode passes through the glass
tube for external connections, so that only the platinum electrode comes
in contact with the electrolyte. Packed in a styrofoam case. Mounted on
a cast iron stand designed for safe clamping. Requires a 6V battery or
low voltage D.C. power supply for operation.
|
HOFFMAN ELECTROLYSIS APPARATUS GLASS PART ONLY
3155-02
Spare glass parts only. Without metal stand.
METAL STAND FOR HOFFMAN ELECTROLYSIS APPARATUS
3155-03
For supporting the above and similar apparatuses. Such as 3155-01.
ELECTRODE PAIR, PLATINUM, SPARE
3155-04
|
For use with Hoffman Electrolysis Apparatus described above 3155-01.
|
ELECTRODE PAIR, CARBON, SPARE
3155-05
|
For use with Hoffman Electrolysis Apparatus described above. Size (l x d),
100 x 5mm. Inserted in a rubber stopper with insulated lead wire.
|
CONDUCTIVITY TESTER
7200-90

This LED (Light Emitting Diode) conductivity indicator is sensitive enough to respond to as little as 0.1 ml of liquid. It detects free H+ ions in water, and will even register low conductivity for 70% ethyl alcohol.
When both probes are in contact with a solid or immersed in a solution, and the material is a:
- Strong conductor - the LED will glow red and blink rapidly
- Weak conductor - the LED will have a steady dull glow
- Non-conductor - the LED will not light up
The Indicator comes with a one-year limited warranty.
(A 9-volt battery is required, but not included)
Contents:
1 Teachers guide, 1 chemplate & 1 conductivity indicator
Back to Top |
UniScience Laboratories
Serving U.S., Canadian & Export Markets
Scientific Equipment & Supplies for Science, Education, Reseach &
Industry
94 Trottier Bay
Fort Garry Ind. Park, Winnipeg, MB, R3T 3Y5, Canada
Tel: 204-269-9644 Fax: 204-269-0674 Toll Free: 877-406-9773
Web site: www.unisciencelab.com Email:
sales@unisciencelab.com
|